Electronics Line Commpact Guia de Instalação

Consulte online ou descarregue Guia de Instalação para Sistemas de segurança - controlo de acesso Electronics Line Commpact. Electronics Line Commpact Installation guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 16
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Quick Start Installation Guide
Vista de página 0
1 2 3 4 5 6 ... 15 16

Resumo do Conteúdo

Página 1

Quick Start Installation Guide

Página 2 - Table of Contents

10 Quick Key Option Name Description and Notes 9>5>1>1 Telephone No. Enter phone number. Use the key to enter "T",",&qu

Página 3 - 1. Introduction

11 Note: Account number 3 is designed for using Follow me feature. It is the only telephone number that can be programmed by the user in the followi

Página 4 - Figure 3: Main board

12 Code Number Authorization Level Description 1 Master Code With the master code, you can edit all other user codes except the Engineer code and t

Página 5 - 3. System Programming

13 9. Press X and select another user. 10. Repeat stages 4–9 to set the code for additional users. Notes: To delete the code, enter: '0000&

Página 6

14 Note If the end user is to perform the self registration on-line then the following CPID and CP Password steps are not required. Program the CPID

Página 7

15 4. Testing the System It is important to fully test the system after installation. CommPact has several testing tools to verify that the system w

Página 8

16 Electronics Line 3000 Ltd. Limited Warranty EL and its subsidiaries and affiliates ("Seller") warrants its products to be free from defec

Página 9

2 Table of Contents 1. Introduction ... 3 2. System In

Página 10

3 1. Introduction Thank you for choosing CommPact wireless intruder Control Panel. This quick start guide manual describes the main steps for install

Página 11 - 3.8. Set/Edit Users

4 Figure 2: Power Supply and Connections Board 1. AC Power Connector (N=Neutral, L=Live) 2. AC Fuse 3. Terminal Block 4. Back Tamper Connector 5.

Página 12 -  To Set/Edit user code

5 3. System Programming 3.1. Keys Menu Navigation Program the CommPact from the keypad located on the main unit (see Table 1). Enter / Save (to move

Página 13 - Connect to MyELAS

6 3.4.1. Detectors The CommPact supports 33 security zones. Only one detector can be registered to each zone. Zones 1-32 are intended for wireless det

Página 14

7 Quick Key Option Name Description and Notes 9>1>1>2 Zone Type The alarm this zone generates 9>1>1>3 Set Setting methods in w

Página 15 - '√'

8 In addition the menu shows the detectors status using the abbreviations in Table 5. Table 5: Abbreviations 3.4.2. Keyfobs The CommPact Control Syst

Página 16

9 Step 3: Testing the keyfobs 1. Go to the main menu and press '√'. 2. Enter your Engineer code (default code '1111'). 3. Enter

Comentários a estes Manuais

Sem comentários