25
ADDRESSES 000-127: ZONE PARAMETERS
000-003: Zone # 1 Parameters
Each zone is individually defined in four parameter addresses. The following four addresses relate to
zone 1 but the method of programming zones 2 - 32 is identical.
000 LCD Zone Descriptor and Entry Delay for Zone #1
Select a zone descriptor and entry delay for zone 1 from the table below. Entry delay options
#1, #2 and #3 are set at addresses 382, 383 and 384, respectively. The four custom LCD
messages can be programmed at addresses 412-475.
No
Delay
Delay
#1
Delay
#2
Delay
#3
Descriptor No
Delay
Delay
#1
Delay
#2
Delay
#3
Descriptor
00 40 80 C0 no message 20 60 A0 E0 LOBBY
01 41 81 C1 1ST FLOOR 21 61 A1 E1 LIVNG ROOM
02 42 82 C2 2ND FLOOR 22 62 A2 E2 MSTR BEDRM
03 43 83 C3 3RD FLOOR 23 63 A3 E3 MAT
04 44 84 C4 4TH FLOOR 24 64 A4 E4 MOTION
05 45 85 C5 BACK DOOR 25 65 A5 E5 NORTH
06 46 86 C6 BASEMENT 26 66 A6 E6 NURSERY
07 47 87 C7 BATHROOM 27 67 A7 E7 OFFICE
08 48 88 C8 BEDROOM 28 68 A8 E8 PANIC
09 49 89 C9 BEDROOM 1 29 69 A9 E9 PERIMETER
0A 4A 8A CA BEDROOM 2 2A 6A AA EA POOL
0B 4B 8B CB BEDROOM 3 2B 6B AB EB ROOF
0C 4C 8C CC COMPUTER 2C 6C AC EC ROOM
0D 4D 8D CD CONFERENCE 2D 6D AD ED ROOM 1
0E 4E 8E CE CORRIDOR 2E 6E AE EE ROOM 2
0F 4F 8F CF DINING 2F 6F AF EF ROOM 3
10 50 90 D0 DOOR 30 70 B0 F0 ROOM 4
11 51 91 D1 EAST 31 71 B1 F1 SHIPPING
12 52 92 D2 EMERGENCY 32 72 B2 F2 SHOP
13 53 93 D3 ENTRANCE 33 73 B3 F3 SLIDE DOOR
14 54 94 D4 EXIT 34 74 B4 F4 SOUTH
15 55 95 D5 EXTERIOR 35 75 B5 F5 STAIRS
16 56 96 D6 FAMILY 36 76 B6 F6 STORAGE
17 57 97 D7 FIRE 37 77 B7 F7 STUDY
18 58 98 D8 FRONT DOOR 38 78 B8 F8 VAULT
19 59 99 D9 GARAGE 39 79 B9 F9 WAREHOUSE
1A 5A 9A DA GUEST ROOM 3A 7A BA FA WEST
1B 5B 9B DB HALL 3B 7B BB FB WINDOW
1C 5C 9C DC HOLDUP 3C 7C BC FC (custom #1)
1D 5D 9D DD INTERIOR 3D 7D BD FD (custom #2)
1E 5E 9E DE KITCHEN 3E 7E BE FE (custom #3)
1F 5F 9F DF LAUNDRY 3F 7F BF FF (custom #4)