ADDRESSES 477-490: RELAY PARAMETERS
Output relay modules are optional add-on peripherals that are connected to the control panel via the
LSCP bus. Relays can be used for various purposes including status indication, additional bell outputs
and access control. Each individual relay is programmed at two addresses.
477 Operation Mode Relay 1(and onboard relay K5)
Each relay can be programmed to activate or deactivate based on specific events or status
conditions. The following table lists the various relay operation mode options. Note: In some
cases, changing the relay’s mode type can activate the relay for the duration of the
cutoff time.
Type Description Activated by Deactivated by Value
Access Access control Pressing SELECT, 9
on the keypad
Cutoff 00
Status System 1 armed System 1 armed System disarmed/ Cutoff 01
Status System 2 armed System 2 armed System disarmed/ Cutoff 02
Status System 3 armed System 3 armed System disarmed/ Cutoff 03
Status System 4 armed System 4 armed System disarmed/ Cutoff 04
Event Silent alarm Keypad Emergency,
Police Emergency, Duress
Cutoff 05
Event System 1 alarm System 1 alarm Cutoff / System 1 disarm 06
Event System 2 alarm System 2 alarm Cutoff / System 2 disarm 07
Event System 3 alarm System 3 alarm Cutoff / System 3 disarm 08
Event System 4 alarm System 4 alarm Cutoff / System 4 disarm 09
Event Fire alarm Fire zone in alarm or keypad fire
emergency
Cutoff 0A
Status System 1 status System 1 Not ready, Pulsing if
system has bypassed zones
System 1 ready without
bypassed zones
0C
Status System 2 status System 2 Not ready, Pulsing if
system has bypassed zones
System 2 ready without
bypassed zones
0D
Status System 3 status System 3 Not ready, Pulsing if
system has bypassed zones
System 3 ready without
bypassed zones
0E
Status System 4 status System 4 Not ready, Pulsing if
system has bypassed zones
System 4 ready without
bypassed zones
0F
Status Power trouble System power trouble (AC or
Battery)
System power is OK 10
Event Telephone trouble Failed communication attempt
(only activated after all message
attempts have failed)
Cutoff 11
Status Pre-alarm Pre-Alarm (if 20 sec bell delay) Bell activated/Bell
Cancel/ System disarm
12
Status Exit/Entry sys. 1 System 1 in Exit/Entry System 1 not in
Exit/Entry
14
Status Exit/Entry sys. 2 System 2 in Exit/Entry System 2 not in
Exit/Entry
15
Status Exit/Entry sys. 3 System 3 in Exit/Entry System 3 not in
Exit/Entry
16
Status Exit/Entry sys. 4 System 4 in Exit/Entry System 4 not in
Exit/Entry
17
Status Bell Bell activated Bell deactivated 18